AVSL 600.103 CMT01 User Manual
Page 6
CMT01 User Manual
AC Current
RANGE
RESOLUTION
ACCURACY (50Hz ~ 60Hz)
20A
10mA
± (2.5% + 13)
200A
100mA
1000A
1A
± (2.5% + 8) @ <800A
For reference only @>800A
Overload Protection: 1200A within 60 seconds.
Jaw Opening: 2.09” (53mm)
Resistance
RANGE
RESOLUTION
ACCURACY
200Ω
0.1Ω
± (1.0% of rdg + 10D)
20kΩ
10Ω
± (1.0% of rdg + 4D)
200kΩ
100Ω
2MΩ
1kΩ
Open Circuit Voltage: about 3V
Overload Protection: 250Vrms DC/AC for 15 sec max
OPERATING INSTRUCTIONS
VOLTAGE MEASUREMENT
1. Connect red test lead to “V” jack, black lead to “COM” jack.
2. Set RANGE switch to desired VOLTAGE position, if the voltage
to be measured is not known beforehand, set switch to the
highest range and reduce it until satisfactory reading is
obtained.
3. Connect test leads to device or circuit being measured.
4. Turn on power of the device or circuit being measured voltage
value will appear on Digital Display along with the voltage
polarity.