AC Current

RANGE

RESOLUTION

ACCURACY (50Hz ~ 60Hz)

20A

10mA

± (2.5% + 13)

200A

100mA

1000A

1A

± (2.5% + 8) @ <800A
For reference only @>800A

Overload Protection: 1200A within 60 seconds.

Jaw Opening: 2.09” (53mm)

Resistance

RANGE

RESOLUTION

ACCURACY

200Ω

0.1Ω

± (1.0% of rdg + 10D)

20kΩ

10Ω


± (1.0% of rdg + 4D)

200kΩ

100Ω

2MΩ

1kΩ

Open Circuit Voltage: about 3V
Overload Protection: 250Vrms DC/AC for 15 sec max


OPERATING INSTRUCTIONS


VOLTAGE MEASUREMENT

1. Connect red test lead to “V” jack, black lead to “COM” jack.
2. Set RANGE switch to desired VOLTAGE position, if the voltage

to be measured is not known beforehand, set switch to the
highest range and reduce it until satisfactory reading is

obtained.

3. Connect test leads to device or circuit being measured.

4. Turn on power of the device or circuit being measured voltage

value will appear on Digital Display along with the voltage

polarity.