Optimal placement of the anchor system is 13” from the front of the anchor plate to water’s edge.
Attach copper wire to the bonding lug and then to your bonding grid
Cold Pin’s should be ½” rebar 6” to 8” long
NOTE: Make sure your anchor plate is level and square with your pool’s edge.
COMPACT SAND
6”
3’
Concrete
Concrete
Cold Pin
Cold Pin
5/8 Bolts
Bonding Lug
Water
Pool Wall
6” Threaded
Anchor’s
3’
3’
Anchor Plate
Overview
Section Detail
COMMERCIAL SERIES C-375/C-450 – TRI POINT ANCHORING SYSTEM
Front of Anchor Plate can be placed 11” to 16” from water’s edge depending on you application