When all the necessary changes are made and checked in the setup

mode, you can jump back to the normal operating mode by pressing

the SETUP key for three seconds. Your Xantrex Battery Monitor is

now ready for use.

F17

Display (backlight) mode. Duration of backlight

activation in seconds after pressing a key on the Xantrex

Battery Monitor. The backlight can also be set to be

always ON or always OFF. In the setting AU the backlight

will be activated automatically when the charge/

discharge current exceeds 1 A or when a key is pressed.

Default

Range

Step size

30 seconds

OFF / 10 – 60 / ON

/ AU

10 seconds

F18

Alarm relay contact polarity. This Function enables

selection between a normally open (NO) or normally

closed (NC) contact. Please note that the NC setting will

slightly increase the Xantrex Battery Monitor’s supply

current in normal operating mode.

Default

Range

NO

NO, NC

F19

Firmware version. Displays the firmware version of the

Xantrex Battery Monitor. No alterations can be made.

Default

x.xx

F20

Setup lock. When this Function is ON, all functions

(except this one) are locked and cannot be altered.

Default

Range

OFF / ON

OFF