Operation – Xantrex Technology 2500 User Manual
Page 6
90-0115-00
10/97 Fltman.pm65
Power Switch
The Power Switch is located on the
front panel. This switch controls ON/OFF
and RESET for the inverter. Expect a 3
second delay when the power switch is
turned ON before the unit is activated.
If the unit is connected to external AC
power, the battery charger and transfer
switch will continue to function, regardless
of the position of the switch.
When external AC power is removed
and the power switch is in the ON position,
the inverter will automatically be ON. If the
switch is in the OFF position and external
AC power is removed, the inverter will be
OFF.
Inverter overload protection, transfer
switching, power sharing and battery
charger regulation will all function automati-
cally.
If installed with the remote control
panel, the power switch on the unit should
be left in the OFF position. Refer to Re-
mote Control Panel, page 7.
OPERATION
6
Power Switch
Fleet Power 1000 shown.