Mandatory Configuration Settings

The following items must be configured in order to use the manual dial-in feature

:

Disable Auto dial-in globally on all the serial ports.

# set serial auto-dialin disable

Disable Auto dial-in on the serial port s0.

# set serial s0 auto-dial-in disable


The following items must be configured in order to use the auto dial-in feature

:

Enable Auto dial-in globally on all the serial ports.

# set serial auto-dialin enable

Enable Auto dial-in on the serial port s0.

# set serial s0 auto-dial-in enable

Set the Auto dial-in protocol.

# set serial s0 auto-dialin-protocol

Set the Auto dial-in Server IP Address.

# set serial s0 auto-dialin-ipaddress

Set the port to the one which the telnet client will be connected.

# set serial s0 auto-port-port

An ERROR message will display if any of the above details are not configured or not valid.



Optional Configuration Settings

The following details are optional configurations:

Enable/Disable Switching-between-Dial-in and the Command Prompt feature.

# set serial escape-monitor

Set the Escape-Monitor-String to switch between Dial-in and Command Prompt sessions.

# set serial escape-string "+++inet"

Set the Serial Dial-in Trigger mode. Dictates the criterion for establishing a connection. The options provided are on
reception of . Refer the command line configuration section for a detail know how of this
command.

# set serial s0 auto-dialin trig-mode

Enable/Disable the Raw mode globally for all Auto-Dial-in sessions.

# set ip telnet raw-mode

Enable/Disable the Raw mode for Auto-Dial-in session on serial port s0.

# set serial s0 raw-dial-in