beautypg.com

How to release the menu protection, How to display the diag menu, Setup (initial settings) – Panasonic AJ-HD130DCP User Manual

Page 23

background image

23

Press the MENU-UP button or MENU-DOWN
button to move the cursor to NO, and press
the SET button.
The menu protection function is now released.

3

Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is now set to the menu protection mode.
When the LOCAL/MENU/REMOTE switch is set
to the MENU position, the VTR is not set to the
menu setting mode, and “MENU PROTECTED”
appears on the video monitor screen.


If, while the menu protection mode is being set,
the LOCAL/MENU/REMOTE switch is set to the
MENU position while the COUNTER button on
the front panel is pressed, the unit is set to the
menu setting mode, and regular menu settings
can be performed.
Perform steps

2

through

7

of “How to perform

settings using the on-screen menu.”

5

Setup (Initial Settings)

How to release the menu
protection

Set the LOCAL/MENU/REMOTE switch to the
MENU position while pressing the COUNTER
button on the front panel.
The unit is set to the menu setting mode, and the
menu screen is displayed on the video monitor.

1

2

MENU PROTECT OK?

2

NO

YES

Perform steps

2

and

3

of “How to protect the

menus.”
The screen for checking the menu protection
function is displayed on the video monitor.

How to display the DIAG menu

Set the LOCAL/MENU/REMOTE switch to the
MENU position while pressing the EJECT
button.
The unit is set to the DIAG display mode, and the
hours meter and deck’s serial number are
displayed on the video monitor.

1

Items with “r” can be reset when servicing is
performed.

DIAG–MENU

HOURS METER

Ser

222222222

H00

OPERATION

00000H

H01

DRUM RUN

00000H

H02

TAPE RUN

00000H

H03

THREADING

00000T

H11

DRUM RUN r

00000H

H12

TAPE RUN r

00000H

H13

THREADING r

00000T

END

While the hours meter is displayed, press the
MENU-UP button or MENU-DOWN button
while pressing the PAGE button.
The software version is displayed on the video
monitor.

2

The hour meter display is restored by pressing
the MENU-UP button or MENU-DOWN button
again while pressing the PAGE button.

DIAG–MENU

VERSION


FRONT

1.

22

-

22

IF

1.

22

-

22

-

2

.

22

AV-SYSCON

1.

22

-

22

-

2

.

22

SERVO

1.

22

-

22

-

2

.

22

END

Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
Operation now returns to the regular mode.

3

This unit comes with a function for displaying the
“HOURS METER,” software “VERSION” and the
deck’s serial number on the video monitor.