4 troubleshooting guide – Panasonic EY6506-U1 User Manual
Page 5
(Refer to WIRING CONNECTION DIAGRAM)
4 TROUBLESHOOTING GUIDE
< TROUBLE >
< CHECK >
< REMEDY >
Does not operate.
NO Replace battery pack.
→
If no less than 12V DC is available across the (+) and (-) terminals,
→
the battery pack is OK.
NOTE:
The battery pack is sold separately as an optional accessory.
See the nearest sales dealer for details. The battery pack has a
limited life.
The pack should be replaced if;
- after being charged for the rated charging time the battery voltage
is less than 12V DC or the usable time is extremely short.
- the battery leaks. Check battery for leaks and terminals for
corrosion.
↓
OK
NO Repair contacts. AND BATTERY PACK.> → Check for proper terminal contacts. ↓ OK NO Contacts in switch block (See WIRING CONNECTION DIAGRAM.) → are defective. Check continuity between following terminals. Replace switch & FET * Inspection of the forward / reverse selection switch. block. When switch handle is depressed all the way: - There should be 0 Ω between (A) - (D) , and between (B) - (C) ; when switch lever is set to forward side. - There should be 0 Ω between (A) - (C) , and between (B) - (D) ; when switch lever is set to reverse side. * Inspection of the brake. When switch handle is not depressed: - There should be 0 Ω between (A) - (B) . ↓ OK NO Replace motor A. Check the condition of carbon brush. → brush assembly. (Do not touch between brush holder and holding spring.) B. There should be 0 Ω between motor lead wire and terminal of brush holder. ↓ OK NO Replace motor Check the condition of rotor if there is any wear, crack and deformation. → rotor assembly. ↓ OK NO Replace motor Check the condition of motor case if there is any crack and deformation. → stator. 5 EY6506-U1