26
Chapter 5
the SP-250 MIDI OUT connector to the MIDI IN connector of the computer. Con-
nect the SP-250 MIDI IN connector to the MIDI OUT connector of the computer.
Standard MIDI settings
When turning the instrument on, the MIDI parameters of the SP-250 are pro-
grammed as follows:
Selecting the transmission channel
The standard MIDI has 16 separate channels available for transmission and recep-
tion of data. SP-250 always receives on all 16 channels, and transmits on a single
channel. To transmit data from the SP-250, you need to choose which of the 16
channels you wish to transmit data on.
Parameter
Setting
Transmission channel
1
Reception channel(s)
All 16 (1-16)*
Local
ON
Omni
OFF
(*) On channel 10, only metronome notes are received (D#5, E5).
MIDI OUT
MIDI IN
MIDI OUT
MIDI IN
- K61 (73 pages)
- GT-4 (2 pages)
- ESX-1 (108 pages)
- Ax3000b (68 pages)
- GT-120 (1 page)
- D1200 (8 pages)
- TP-2 (4 pages)
- BA-40 (2 pages)
- SP 250 (184 pages)
- D12 (2 pages)
- AX10g (2 pages)
- D1200mkii (8 pages)
- CX-3 (40 pages)
- C-520 (298 pages)
- MS2000 (6 pages)
- M3 (237 pages)
- M3 (32 pages)
- OASYS musical instruments (241 pages)
- EASYSTART AX3B (3 pages)
- C-320 (189 pages)
- AX10A (39 pages)
- KONTROL49 (4 pages)
- TRITON Extreme music workstation/sampler (148 pages)
- Pa800 (9 pages)
- EMX-1 (99 pages)
- TRITON STUDIO music workstation (305 pages)
- microX (134 pages)
- TouchView Trinity (160 pages)
- Ax3000g (67 pages)
- Electribe EM-1 (56 pages)
- METROGNOME MM-1 (2 pages)
- Kaossilator Dynamic Phrase Synthesizer (4 pages)
- Kp3 (6 pages)
- D8 (76 pages)
- sampler (167 pages)
- KPC-1 EFG (95 pages)
- AX10B (40 pages)
- TRITON Musical Instrument (91 pages)
- D3200 (200 pages)
- X50 (132 pages)
- KM-2 (35 pages)
- PXR4 (99 pages)
- DT-10 (3 pages)
- D888 (52 pages)