18

Table D

H +

H

1

Maximum

V Minimum

feet

(meter)

feet

(meter)

5

(1.524)

Elbow Only

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

H + H

1

= 20 feet (6.096 m) Max.

V + V

1

+ H + H

1

= 40 ft. (12.192 m) Max.

Example: If 20 feet total (H+H

1

) horizontal vent run is needed, then

4 feet minimum of (V) vertical vent will be required.

This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V) vertical,

you are allowed 5 feet of (H+H

1

) horizontal run up to a maximum total

horizontal run of 20 feet.

An elbow is acceptable as 1 foot of vertical rise except where an elbow

is the only vertical component in the system. See Figure 36.

Table C

H

+H

1

Maximum

H

Maximum

V Minimum

feet

(meter)

feet

(meter)

feet

(meter)

5

(1.524)

2

(0.610)

1

(0.305)

10

(3.048)

4

(1.219)

2

(0.610)

15

(4.572)

6

(1.829)

3

(0.914)

20

(6.096)

8

(2.438)

4

(1.219)

V + V1 + H + H1 = 40 feet (12.2 m) Max

H = 8 feet (2.438 meters) Max.

H + H1 = 20 feet (6.096 meters) Max.

Example: If 20 feet total (H+H

1

) horizontal vent run is needed,

then 4 feet minimum of (V) vertical vent will be required.
This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V)

vertical, you are allowed 5 feet of (H+H

1

) horizontal run up to a

maximum total horizontal run of 20 feet.

u

When using Secure Flex, use Firestop / Spacer SF4.5VF

v

When using Secure Flex, use Firestop / Spacer SF4.5HF

H1

V

V1

H

V

H1

H

V1

Figure 30 - Side Vent - THREE ELBOWS

Figure 31 - Top Vent - THREE ELBOWS

u

Ceiling

Firestop / Spacer

(SV4.5VF)

v

Wall Firestop/

Spacer (SV4.5HF)

u

Ceiling Firestop /

Spacer (SV4.5VF)

u

When using Secure Flex, use Firestop / Spacer SF4.5VF

v

When using Secure Flex, use Firestop / Spacer SF4.5HF

u

Ceiling

Firestop / Spacer

(SV4.5VF)

v

Wall Firestop/

Spacer (SV4.5HF)

VERTICAL VENT FIGURES / TABLES (CONTINUED)