17 – lock/fader, Fr setup status – Sony SRP-X700P User Manual
Page 17
– 17 –
LOCK/FADER
Status of the PANEL LOCK and that of FADER MODE are indicated by the 8-bit data.
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
0
1
0
0
0
0
PANEL LOCK
FADER
When bit 0 is ‘1’, it indicates that the fader is in the ACTIVE mode. When bit 0 is ‘0’, it indicates that the fader is in the INACTIVE mode.
When bit 1 is ‘1’, it indicates that operations from the front panel of the SRP-X700P are in the LOCKed state. When bit 1 is ‘0’, it indicates
that operations from the front panel of the SRP-X700P are in the UNLOCKed state.
Bit-2 to bit-7 are fixed all the time.
FR SETUP STATUS
The progress status of the feedback reducer setup is indicated in the 16 steps.
The “Finished (30[H])” flag indicates the setup is completed.
Progress
Progress
status
status
Finished
30[H] (‘0’)
9
39[H] (‘9’)
1
31[H] (‘1’)
10
3A[H] (‘:’)
2
32[H] (‘2’)
11
3B[H] (‘;’)
3
33[H] (‘3’)
12
3C[H] (‘<’)
4
34[H] (‘4’)
13
3D[H] (‘=’)
5
35[H] (‘5’)
14
3E[H] (‘>’)
6
36[H] (‘6’)
15
3F[H] (‘?’)
7
3
3
7[H] (‘7’)
] (‘8’)
16
40[H] (‘@’)
8