5) hri font, 6) check character, 7) beginning of the bar code data sequence – Seiko BX-900 User Manual
Page 80
(5) HRI font: DC4 DC4 F
Format:
ASCII
DC4
DC4
F
n
Hex
14
14
46
n
Decimal
20
20
70
n
Function: Selects the font of printing the HRI.
n = 0: Currently selected font
1: OCR-A
2: OCR-B
This setting is not valid for Postnet or Element.
(6) Check character: DC4 DC4 C
Format:
ASCII
DC4
DC4
C
n
Hex
14
14
43
n
Decimal
20
20
67
n
Function: Specifies whether to add a check character automatically.
n = 0: No check character is added. (If a check character is needed, the
user must send bar code data.)
1: A check character is added. (The check character is not printed
in the HRI when Code 93 or Code 128 is selected.)
If the Codabar or Element is selected, no check character is added regardless of
this setting.
The following shows the methods of determining the check characters and bar code
types. (For details, see “Calculating the check character” below.)
Modulus 10
Industrial 2 of 5, Interleaved 2 of 5, Matrix 2 of 5, EAN, UPC,
Postnet
Modulus 11
Code 11 (Dual Check character)
Modulus 16
Codabar
Modulus 43
Code 39
Modulus 47
Code 93 (Dual Check character)
Modulus 103 Code 128
(7) Starting the bar code data sequence: ESC SI
Format:
ASCII
ESC
SI
Hex
1B
0F
Decimal
27
15
Function: Indicates the starting the bar code data sequence.
Data between this and the end command of the bar code data sequence
is regarded as bar code data.
This command is valid only when #27 BARCODE/LABEL MODE is
set to MODE 2 in the EXTENDED SETUP MODE.
72
9. Bar code and enlarged character