A DVA N C E D F E AT U R E S

PAG E 5

VG A 4 4 I N S TA L L AT I O N & O P E R AT I O N M A N UA L

RS232

The AMAV switcher can be controlled via the RS232 serial control port to
allow for interfacing to a PC, Crestron or similar third party control system.

The serial communication parameters are 9600 baud, 8 bit, No Parity and 1
stop bit – this is often referred to as 9600 8N1. When the unit recognises
a complete command it will perform the requested action – there is no
delimiter character required.

The unit does not send out a message when a value is changed from the
front panel or by IR control. If the unit needs to be controlled from the front
panel in addition to the RS232 control, you would need to regularly poll the
units’ status to ensure the control system accurately reflected the current
settings.

COMMANDS

To Switch Inputs to Outputs

SBIøXOøY

Where X is Output Number (1-4) and Y is Input

Number (1-4)

Unit will respond with

SBUDøXOY

Where X is Output Number (1-4) and Y is Input

Number (1-4)

Example : Send Input 1 to Output 4

SBIø1Oø4

- Send

SBUDø1O4

- Rcvd

STANDBY MODE

Note : Turning the unit System Power Off over RS232 will blank

the displays leaving only the Power Switch LED on. Hard

resetting the unit when in System Power Off mode will return the

unit to normal operation and unlock the front panel.

Even while the unit is turned off by RS232 it will continue to accept and act

upon switching commands. This allows you to set up a ‘scene’ before soft

powering on the unit and enabling the video outputs. The unit will still return

status and change messages in response to commands sent while in System

Power Off mode.

SBSYSMON

- Put system into Standby (Soft Power Off)

SBSYSMOF

- Bring unit out of Standby (Soft Power On)

Unit will respond with

SBALOFAK

- Unit is in Standby

SBALONAK

- Unit is no longer in Standby

Example : Put Unit in Standby (Soft Power)

SBSYSMOF

- Send

SBALOFAK

- Rcvd

FRONT PANEL LOCk

Note : Hard resetting the unit will unlock the Front Panel controls.

.

SBSYSMLK

- When front panel is locked, changes can only be

made by RS232

SBSYSMUK

- Front Panel Unlock

Unit will respond with

SBSYSLOK

- Front Panel has been Locked

SBSYSULK

- Front Panel has been Unlocked

Example : Lock Front Panel Buttons

SBSYSMLK

- Send

SBSYSLOK

- Rcvd

UNIT RESET

SBSYSMLK

- Reset every output to Input 1

Unit will respond with

SBRSTACK

- Unit has reset each Output to Input 1

Example : Reset all outputs to Input 1

SBALLRST

- Send

SBRSTACK

- Rcvd