beautypg.com

Electromagnetic lock installation manual, Notice, Regular maintenance – SECO-LARM USA E-941DA-1K2P User Manual

Page 4: Troubleshooting, Warranty, Ul certification, Problem, Possible cause, Solutions

background image

ELECTROMAGNETIC LOCK Installation Manual

SECO-LARM U.S.A., Inc.

Page 4

E-941SAd.pmd

PITGW1

®

NOTICE

The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement. For this reason,
SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not
responsible for misprints or typographical errors.
Copyright © 2003 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced
or copied, in whole or in part, without the written permission of SECO-LARM.

REGULAR MAINTENANCE

• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-

abrasive, non-corrosive cleaner.

• Apply a light coat of a silicon lubricant to prevent rust. Wipe away the excess.

• Check that the armature plate is securely attached to the door, yet can pivot slightly around the

armature screw.

• Check that the electromagnet is securely attached to the door frame.

TROUBLESHOOTING

Problem:

Door does not lock

Door locks, but can be

easily forced open

Delay in door releasing

Possible cause:

No power

Poor contact between

electromagnet and

armature plate

Incorrect voltage

setting

A secondary diode was

installed across the

electromagnet

Solutions:

• Check to make sure the wires are

securely tightened to the terminal block

• Check that the power supply is connected

and operating

• Make sure the lock switch is wired

correctly

• Make sure the electromagnet and

armature plate are properly aligned

• Make sure the contact surfaces of the

electromagnet and armature plate are

clean and free from rust

• Check the power leads with a meter, and

make sure 12VDC or 24VDC is present

• The electromagnet is fitted with a metal

oxide varistor to prevent interference, so

do not install a secondary diode

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

®

U.S.A., Inc.

U.S.A., Inc.

U.S.A., Inc.

U.S.A., Inc.

U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326

Website: www.seco-larm.com

E-mail: [email protected]

WARRANTY:

ENFORCER Electromagnetic Locks are warranted against defects in

material and workmanship while used in normal service for a period of one (1) year from the
date of sale to the original customer. Our obligation is limited to the repair or replacement of any
defective part if the unit is returned, transportation pre-paid, to SECO-LARM.

UL CERTIFICATION

E-941SA-600 and E-941SA-1200 electromagnetic locks conform to UL/10B “Fire Tests of Door

Assemblies” and UL/10C “Positive Pressure Fire Tests of Door Assemblies” for swinging door

assemblies. They are also classified in accordance with the Uniform Building Code standard 7-2.

This manual is related to the following products: