Connecting to the s/pdif header, Connecting to the serial headers, Connecting to the parallel port header – Intel D510MO User Manual
Page 36: S/pdif header, Serial port headers (com 1 and com 2), Parallel port header

Intel Desktop Board D510MO Product Guide
36
Connecting to the S/PDIF Header
Before connecting to the S/PDIF connector, observe the precautions in "Before You
Begin" on page 23. See Figure 12, B on page 34 for the location of the S/PDIF header.
Table 8 shows the pin assignments for the S/PDIF header.
Table 8. S/PDIF Header
Pin Signal
Name
1 Ground
2 S/PDIF
out
3 VCC
(5V)
Connecting to the Serial Headers
Before connecting to the serial headers, observe the precautions in "Before You Begin"
on page 23. See Figure 12, C on page 34 for the location of the serial headers.
Table 9 shows the pin assignments for the serial headers.
Table 9. Serial Port Headers (COM 1 and COM 2)
Pin
Signal Name
Pin
Signal Name
1
DCD (Data Carrier Detect)
2
RXD# (Receive Data)
3
TXD# (Transmit Data)
4
DTR (Data Terminal Ready)
5
Ground
6
DSR (Data Set Ready)
7
RTS (Request To Send)
8
CTS (Clear To Send)
9
RI (Ring Indicator)
10
Key (no pin)
Connecting to the Parallel Port Header
Before connecting to the parallel port header, observe the precautions in "Before You
Begin" on page 23. See Figure 12, D on page 34 for the location of the parallel port
header.
Table 10 shows the pin assignments for the parallel port header.
Table 10. Parallel Port Header
Pin
Standard Signal Name
ECP Signal Name
EPP Signal Name
1
STROBE# STROBE# WRITE#
2 AUTOFD#
AUTOFD#,
HOSACK
DATASTB#
3
PD0 PD0 PD0
4 FAULT#
FAULT#,
PERIPHREQST# FAULT#
5
PD1 PD1 PD1
6 INT#
INT#,
REVERSERQST# RESET#
7
PD2 PD2 PD2
8
SLCTIN# SLCTIN# ADDRSTB#