English – InFocus DS 12DM User Manual
Page 9
English
8
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Lights continuously
Before
charging
While
charging
Charging
complete
Charging
impossible
Blinks
(RED)
Lights
(RED)
Blinks
(RED)
Flickers
(RED)
Lights
(GREEN)
Malfunction in the bat-
tery or the charger.
The battery temperature
is high, making recharg-
ing impossible.
Table 1
Indications of the pilot lamp
Charging
impossible
(2) Regarding the temperatures of the rechargeable
battery
The temperatures for rechargeable batteries are as
shown in the table below, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 2 Recharging ranges of batteries
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown
in Table 3.
Table 3 Charging time (At 20°C)
NOTE
The charging time may vary according to
temperature and power source voltage.
4. Disconnect the charger’s power cord from the
receptacle
5. Hold the charger firmly and pull out the battery
Temperatures at
Rechargeable batteries
which the battery
can be recharged
EB912S, EB914S, EB914, EB9B,
EB1212S, EB1214S, EB1214L,
–5°C – 60°C
EB1220BL
EB9H, EB926H, EB930H,
0°C – 45°C
EB1222HL, EB1226HL, EB1230HL
NOTE
After operation, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new batteries,
etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary phenomenon,
and normal time required for recharging will be
restored by recharging the batteries 2 – 3 times.
How to make the batteries perform longer.
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a
while.
CAUTION
⅜ If the battery is charged while it is heated because
it has been left for a long time in a location subject
to direct sunlight or because the batetery has just
been used, the pilot lamp of the charger lights up
green. In such a case, first let the battery cool, then
start charging.
⅜ When the pilot lamp flickers in red (at 0.2-second
intervals), check for and take out any foreign objects
in the charger’s battery installation hole. If there are
no foreign objects, it is probable that the battery
or charger is malfunctioning. Take it to your
authorized Service Center.
Charger
UC14YFA
Battery
EB912S, EB914S,
EB914, EB1212S,
Approx. 30 min.
EB1214S, EB1214L
EB9B, EB1220BL
Approx. 50 min.
EB9H, EB1222HL
Approx. 55 min.
EB926H, EB1226HL
Approx. 60 min.
EB930H, EB1230HL
Approx. 70 min.