Step 5 – work with the channel processing – iLive AP7141 User Manual
Page 15
iLive Fixed Format Getting Started Guide
15
AP7141 iss.2
Step 5 – Work with the channel processing
Access the Preamp, EQ and dynamics
Press a strip
SEL
key. Press the key again to turn it off or
press another to access a different channel.
*
You can press and hold any
SEL
key in the Processing
Block to temporarily send it to the PAFL system to listen to
and meter the signal at that point in the signal path.
The Channel Processing Block displays the current
settings for that channel. Controls illuminate if available.
The TouchScreen
provides an alternative graphical view
and access to the input and insert patching, delay setting
and changing the name and colour. Touch the screen to
open the different processing views. Touch Return to return
to the main page.
Note
- To view the processing parameters on the screen
make sure all the screen keys are turned off. The
SEL
keys
will not access the processing if you leave the screen in
NAME/COLOUR, MIXRACK
or
SURFACE
.
The
PREAMP
screen lets you patch the Source to the DSP
channel, control the remote analogue mic preamp, adjust
channel Trim and Polarity, set name and colour, and adjust
the HPF (high pass filter).
Choose to present either the preamp controls (
Gain
, Pad,
48V, Polarity) or trim controls (
Trim
, Polarity) on the Surface
PREAMP section. This lets both FOH and Monitor engineers
work with their own independent trim controls once the Gain
has been set. All channels may be globally set to present
either the Preamp or Trim controls from the
MIXRACK
SETUP / Mixer Pref
screen. Once set, individual channels
may be changed from within their
PREAMP
screen
GEQ on faders
Press a mix master
SEL
key to access the processing for
that master. The GEQ is controlled from the screen or on the
faders by pressing the Surface GEQ FADER FLIP key.
Press the key to toggle between screen and fader control.
In GEQ on faders mode - The EQ frequencies are indicated
on the strip LCDs above. The strip meters display the RTA
(PAFL signal if one is selected). The red PK meters display
the dominant frequency if this option has been set in the
SURFACE / Preferences
screen.
The fader on the right becomes the master or currently
active send level for the mix. Hold down ALT VIEW to
display the EQ dB settings on the strip LCDs. Press the strip
SEL
keys to reset individual frequency bands to 0dB.
MUTE
SEL
MIX
MIX
PAFL
Due to its compact size, the
smaller iLive surfaces do not
provide all the physical controls.
Access these parameters using
the TouchScreen.
*
Processing
SEL
keys
Channel Processing Block