VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO4837R
7
BACK VIEW OF CABINET
AFTER POSITIONED ON
CUSTOMER-SUPPLIED COUNTER/BASE
15”
MINIMUM
AIR
EXHAUST
SPACE
9 1/2”
19” MINIMUM
AIR EXHAUST
SPACE
45” MINIMUM MAINTENANCE
ACCESS SPACE
25” MINIMUM AIR
INTAKE SPACE
9 1/2”
FACIA ENCLOSURE
13”
MINIMUM
AIR INTAKE
SPACE
Warning: The minimum intake and exhaust areas must be allowed (as illustrated
below) or case temperatures may fluctuate beyond safe parameters.
15” MINIMUM
MAINTENANCE
ACCESS SPACE
2”
NOTES:
1. BACK OF CABINET MUST BE VENTED A MINIMUM OF 13” x 25” FOR AIR INTAKE.
2. BACK OF CABINET MUST BE VENTED A MINIMUM OF 19” x 21” FOR AIR EXHAUST.
3. BACK OF CABINET MUST PROVIDE A MINIMUM OF 15” x 45” FOR MAINTENANCE ACCESS. THIS AREA
(AS DIMENSIONED BELOW) WILL ALLOW SERVICE TO SLIDE OUT CONDENSING UNIT.
4. SEE REFRIGERATION FUNDAMENTALS FOR VIEW OF CONDENSING UNIT AFTER SLIDE-OUT.
5. AIR
INTAKE
(ILLUSTRATED
BELOW).
6.
AIR EXHAUST
(ILLUSTRATED
BELOW).