beautypg.com

Ives 232TGSL User Manual

Page 3

background image

3

LUBRICATION

Ingersoll--Rand No. 50

Ingersoll--Rand No. 100

Always use of an air line lubricator. We recommend the
following Filter--Regulator--Lubricator Unit (FRL):

Inside USA use FRL unit # C28--04--FKG0--28

Outside USA use FRL unit # C28--C4--FKG0

After each eight hours of operation, if an airline
lubricator is not used, remove the Oil Chamber Plug (17)
and fill the oil chamber with Ingersoll--Rand No. 50 Oil.

After each eight hours of operation, or as experience
indicates, inject about 4 cc of the Ingersoll--Rand No. 100
Grease into the Grease Fitting (16).

INSTALLATION

(Dwg. TPD905--2)

F

L

R

Main Line(s) Inner Ø

to be 3X Size of

Air Tool’s Inlet Ø

To Air

System

To Air

Tool

Lubricator

Emergency

Shut--Off

Valve

Regulator

Filter

Compressor

FRL

Drain Regularly

Branch Line(s) Inner Ø

to be 2X Size of

Air Tool’s Inlet Ø

SPECIFICATIONS

Model

Handle

Drive

Recommended Torque Range

I.D.

Type

inches

ftSlb (NSm)

232TGSL

pistol

1/2 sq.

40--400 (64--542)