P3 p1 – Intelligent Motion Systems MForce PowerDrive Plus MForce Series Microstepping PowerDrive User Manual
Page 15
1-9
Part 1: Hardware Specifications
Pin Assignment and Description
P1 12-Pin Locking Wire Crimp Connector Option - Power, I/O and SPI
Communications
Pin Assignment - P1 Power, I/O and SPI
Connections
Pin #
Function
Description
Pin 1
N/C
No Connect
Pin 2
N/C
No Connect
Pin 3
Opto Reference
The Signal applied to the Optocoupler Reference will
determine the sinking/ or sourcing configuration of the inputs.
To set the inputs for sinking operation, a +5 to +24 VDC
supply is connected. If sourcing, the Reference is connected
to Ground.
Pin 4
Step Clock/Channel
A/ Clock Up
Step Clock input. The step clock input will receive the clock
pulses which will step the motor 1 step for each pulse. It
may also receive quadrature and clock up type inputs if so
configured.
Pin 5
Enable
Enable/Disable Input will enable or disable the driver output
to the motor. In the disconnected state the driver outputs are
enabled in either sinking or sourcing configuration.
Pin 6
Direction/Channel B/
Clock Down
Direction input. The axis direction will be with respect to the
state of the Direction Override Parameter. It may also receive
quadrature and clock up type inputs if so configured.
Pin 7
+5 VDC Output
Supply voltage for the MD-CC300-000 Cable ONLY!
Pin 8
SPI Clock
The Clock is driven by the SPI Master. The clock cycles once
for each data bit.
Pin 9
GND
Communications Ground.
Pin 10
MISO
Master-In/Slave-Out. Carries output data from the MFM back
to the SPI Master.
Pin 11
CS
SPI Chip Select. This signal is used to turn communications
on multiple MFM units on or off.
Pin 12
MOSI
Master-Out/Slave-In. Carries output data from the SPI Master
to the MFM.
Table 1.2.7: P1 Connector – Power, I/O and SPI Communications
NEED A CABLE?
The following cables
and converters are
available to interface
with P1:
12-Pin Locking Wire Crimp
PD12-1434-FL3
P3
P1
1 3 5 7 9 11
2 4 6 8 10 12
NEED A CABLE?
The following cables
and converters are
available to interface
communications with
USB to SPI:
MD-C300-000
10-Pin IDC to 12-Pin Locking
Wire Crimp Adapter
All SPI Communications will
connect to the P1 Connector.
An adapter is available to interface
the MD-CC300-000 to the 12-Pin
Locking Wire Crimp connector.
MD-ADP-1723C
This adapter may be used in
conjunction with the following
Prototype Development cables to
interface power and logic:
PD12-1434-FL3 (10')
ADP-3512-FL (12")
See Appendix A for details.
Figure 1.2.2: P1 — 12-Pin Locking Wire Crimp Pin Configuration
Recommended Connector Shell and Pins
Shell: AMP P/N 1-794617-2
Pins: 12 x AMP P/N 794610-1
Wire: 22 AWG Shielded Twisted Pair