Configuring the host files – IntraServer Technology ITIpci 5100G/GF User Manual
Page 25
LSI Logic Corporation
Page 25 of 56
# sync
# sync
# halt
Then, at the ok prompt, use the following command to list the system
devices:
ok show-devs
ITI-5100G/GF adapter output will be displayed. Sample PCI examples are
shown on the next page.
For PCI systems, " ethernet@1 " identifies the PCI ITI-5100G/GF
adapter:
/SUNW,ffb@1e,0
/SUNW,UltraSPARC-II@0,0
/pci@1f,2000
/pci@1f,4000
/counter-timer@1f,1c00
/virtual-memory
/memory@0,60000000
/aliases
/options
/openprom
/chosen
/packages
/pci@1f,2000/ethernet@1
/pci@1f,4000/scsi@3
/pci@1f,4000/network@1,1
/pci@1f,4000/ebus@1
/pci@1f,4000/scsi@3/tape
/pci@1f,4000/scsi@3/disk
/pci@1f,4000/ebus@1/SUNW,CS4231@14,200000
....
If the appropriate ITI-5100G/GF device is not listed, check that the adapter is
installed and properly seated. Then restart the system and re-install the
adapter software.
Configuring the Host Files
Once the ITI-5100G/GF adapter software is installed on your system, it must
be configured. To ensure proper adapter performance, configure the host files
and driver parameters as described in the following sections.