Buccaneer gt, falcon gte, 7installation 2.8 example of installation, Example: buccaneer gt – IDEAL INDUSTRIES BUC5034 User Manual
Page 7: Installation, assembly & servicing
Buccaneer GT, Falcon GTE
- Installation, Assembly & Servicing
7
INSTALLATION
2.8 Example of Installation
The boiler-to-tank connection kit is placed between points A and B between the boiler and the heating circuit.
Example: Buccaneer GT
28
1
2
32
17
9
57
24
25
7
27
27
26
A
B
9 29
30
a
b
c
d
e
2 cm
(54)
BUC5003
Cold water
Domestic hot
water tank
1
2
7
9
17
24
25
26
27
28
29
Heating outlet
Heating return
Automatic bleeder valve
Valve
Draining tap
Exchanger primary input
Exchanger primary output
Hot water filling pump
Non-return valve
Cold water intake of hot water tank
Pressure reducer if mains pressure > 5.5 bar
30
32
54
57
A-B
Sealed safety device calibrated to 7 bar
a Cold water inlet with a non return valve
b Connection to the cold water intake of the tank
c Stop valve
d Safety valve and manual draining tap
e Draining outlet
Domestic hot water looping pump (optional)
YA type load breaking device (health regulations)
Domestic hot water outlet (
)
Points for connecting to the heating installation