Stp service continued – IDEAL INDUSTRIES 45-935 User Manual
Page 15
STP Service continued
Blade Replacement
1. Electronically set strip length to 6". This moves the stop bar all the way back allowing more room to replace the blades.
2. Disconnect power. (rear gripper will retract all the way back).
3. Disconnect
air.
4. Open lid. Note: Open lid by pressing button and lifting lid.
5. Unplug blade electrical connection and cut off connector (a new connector is supplied with replacement blade set).
6. Remove the two hold-down clamps.
7. Unplug the wire connection between the two blades
(inside silicone tube).
CUT OFF CONNECTOR