Final water connection – InSinkErator 1100 User Manual
Page 9
9
Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
Property Damage: Join remaining tube
to cold water supply only.
C
■
■
Turn on the cold water supply.
■
■
Depress the dispenser’s HOT handle
and hold it until water flows from the
spout (approximately 1 to 2 minutes).
■
■
Run the water for at least 2 minutes
to flush lines (both the hot and cold
handles independently if applicable).
B
A
■
■
Check all connections to ensure they are
tight and that there are no leaks.
■
■
Plug in instant hot water tank.
Water will be cold at first.
Allow 12-15 minutes for water to reach
target temperature.
Gurgling or hissing is normal during the
initial heating cycle.
6
Brass Nut
Ferrule
Brass Insert
Plastic
tube
■
■
Install a T-fitting (not included)
onto the cold water supply line.
■
■
Install dedicated water control valve
with 3/8" compression fitting.
■
■
At the end of the white 3/8" tube from the
filter or quick-connector, slide the supplied
brass nut and ferrule over the tube and
then push in the brass tube insert.
■
■
Insert the white 3/8" tube into the 3/8"
compression fitting and tighten.
Property Damage: A standard grounded outlet within
30" of the dispenser is required under the sink. Do
not use an extension cord set with the dispenser.
If the water coming from the faucet is not hot 15 minutes after the unit
has been plugged in – or for other issues related to the operation of your
instant hot water dispenser – refer to the “Troubleshooting” section on Page 14.