Options – Ingersoll-Rand 7120 User Manual
Page 72
OPTIONS
7/120 (P425AWIR), 9/110 (XP375AWIR), 10/105 (HP375AWIR), 14/85 (VHP300AWIR),
7/170 (P600WIR), 10/125 (HP450WIR), 14/115 (VHP400WIR)
69
MAINTENANCE
Daily maintenance:
Verify, during full–load (maximum compressed air delivery) that
the IQ system filter restriction indicators do not show excessive
restriction.
Restriction indicators for primary and secondary filters are
located on the filter heads. If so equipped, an automatic
restriction indicator is located behind the filter mounting bracket
and will shut down the compressor if restriction exceeds
recommended values.
Weekly Maintenance:
S
Verify that the piping from the water separator and filters to
the exhaust system is not clogged.
Yearly Maintenance:
The normal maintenance interval on the primary and secondary
IQ System filters is one year, or earlier if pressure drop becomes
excessive.
Restriction indicators for the filters are mounted on the filter
heads. If so equipped, an automatic restriction indicator located
behind the filters will shut down the compressor if restriction
exceeds recommended values.
Filter replacement.
S
Remove all wires and hoses connected to drains on bottom
of each filter housing. Inspect fittings and hoses for any
blockage. Clean if necessary.
S
Using a chain wrench or similar tool, loosen the housing. The
housing should be removed by hand after loosening, taking care
to prevent the housing from falling to the floor panel.
S
Lower the housing to floor panel. Remove and replace the
filter element, being careful not to damage outer wrap.
S
Put a small amount of petroleum jelly or other non–synthetic
grease on the element o–ring to aid installation into the filter
head.
S
Replace housing making sure not to overtighten.
S
Repeat the above procedure on the remaining filter element.
S
Rec onnect all wires and hoses to drains on bottom of each
filter housing.