beautypg.com

Marantz STRIKER S160 User Manual

Page 6

background image

c

learances

To

c

omBusTiBles

WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN

THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE

CONSTRUCTION IS NOT LESS THAN SHOWN.

Floor Protection

USA - The floor in front and under the heater must be pro-

tected with a minimum of 3/8” thick noncombustible material.

The covering must extend 16” in front of the door opening

of the heater and 8” to either side of the door opening and

5-1/2” to the rear or to the wall, whichever is smaller. In all

installations a 16” minimum hearth extension (in front of

the stove) is required as measured from the door opening

of the unit.

Canada - The floor in front and under the heater must be

protected with a minimum of 3/8” thick noncombustible

material. The covering must extend 457 mm in front of the

door opening of the heater and 200mm to either side of the

stove body and 200 mm to the rear or to the wall, whichever

is smaller. In all installations a 457mm minimum hearth

extension (in front of the stove) is required as measured

from the door opening of the unit.

Reduced Clearances

Clearances to combustible surfaces can be reduced with the

use of listed double wall connector pipe. See the clearances

with double wall pipe on the following page.

Alcove Clearances

Single Wall Pipe - Minimum 48"(1219mm) width, maxi-

mum 48" (1219mm) depth. Minimum ceiling height is 72”

(1829m).

Double Wall Pipe - Minimum 44"(1117mm) width, maxi-

mum 48" (1219mm) depth. Minimum ceiling height is 72”

(1829m).

Mobile Home Installations

All mobile home installations require an outside air kit (part #

71111 or 71112). The stove must be bolted to the floor and

grounded to the chassis of the mobile home.

WARNING: DO NOT INSTALL IN SLEEPING ROOM OF A

MOBILE HOME.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE

HOME FLOOR, WALL, AND CEILING/ROOF MUST BE

MAINTAINED.

Approved Chimney* - Your stove is approved for use with

Class A, UL 103HT Chimney and double wall connector pipe

from Security™ Chimneys.

Clearances to connector pipe shall be measured from the

flue collar of the stove.

Chimney & Connector

Minimum 6" diameter, minimum 24 MSG black steel con-

nector pipe with listed factory-built chimney suitable for use

with solid fuels or masonry chimney. Horizontal connection

not tested, refer to local building codes for installation. Re-

strictions apply! Read instructions before installing.

Clearance dimensions are to 6” (152mm) flue collar. If a

single wall connector pipe with shield is used, a 1 inch air

space is needed between pipe and shield. Shield attaches

to rear of stove pipe and must run from stove top to ceiling.

Pipe shield shall be UL listed.

Residential chimney systems must be from the same brands

as listed for mobile homes but connector pipe may be double

wall, single wall or single wall with shield as listed above.

Connector pipe and chimney must be of the same brand.

Components Required For Installation

Legs AND Bottom Heat Shield or Pedestal Base.

If optional blower is NOT used, Rear Heat Shield Block Off

Plate shall be installed.

* Other approved chimney brands are Projet, Jakes Evans/GSW, Dura-vent,
Metal Fab, Ameri-Tec, Metalbestos and Industrial Chimney (ICC).