15
GB
Real time clock
Minimum 10 years lifetime.
Supply voltage
+5 VDC from PLC system CPU port via com-
munication cable.
Internal logic voltage
+5 VDC ±5%.
Power consumption
MAC 10/MTA-10: 70 mA.
MAC 12/MTA-12: 150 mA.
Ambient temperature
0º to +50ºC
Storage temperature
-20º to +60ºC
Air humidity
Max 90% without condensation.
Interference test
Interference tested for external noise according
to: EN 50081-1 emission and EN 50082-2
immunity.
The product have passed and comply with spe-
cifications of the above tests. The product must
only be used for applications covered by these
standards.
EMC-tests on the terminal
G & L Beijer Electronics AB confirm that the
terminals conforms with the essential protection
requirements in article four of the directive
89/336/EEC.
Mac10eng Seite 15 Freitag, 5. Februar 1999 3:29 15