SS-GME8

SS-GME8

www.goodmanmfg.com

3

P

roduct

S

PecificationS

P

roduct

S

PecificationS

s

peciFications

GME8

0603B*B

GME8

0805C*B

GME8

0805D*A

GME8

1005C*B

Performance Data
Input¹

60,000

80,000

80,000

100,000

Output¹

48,000

64,000

64,000

80,000

LP Output¹

48,000

64,000

64,000

80,000

AFUE²

80

80

80

80

Tons AC @ 0.5” ESP

3

5

5

5

Temperature Rise Range (°F)

20 - 50

35 - 65

30 - 60

35 - 65

Circulator Blower
Size (D x W)

10 X 8

10 X 10

10 X 10

10 X 10

HP

1/2

1

1

1

Speed

5

5

5

5

Vent Diameter³

4

4

4

4

No. of Burners

3

4

4

5

Disposable Filter (in²)

290

480

480

480

Electrical Data
Min. Circuit Ampacity

8.2

14.8

14.8

14.8

Max. Overcurrent Protection⁵

15

15

15

15

Ship Weight (lbs)

98

116

123

120

¹ Low-fire rate is 75% of high-fire rate.
² DOE AFUE based upon Isolated Combustion System (ICS).
³ Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI

Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be deter-

mined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

⁵ Refers to maximum recommended fuse or circuit breaker size; may use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.
• Gas Service Connection ½” FPT
• Important: It is required to size overcurrent protection device and wires properly and make electrical con-

nections in accordance with the National Electrical Code and/or all existing local codes.