beautypg.com

Installation instructions, Installation, Fuel bed arrangement – Stovax F40 User Manual

Page 13: Door replacement 17

background image

IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY

REQUIRE ATTENTION - SEEK EXPERT ADVICE.

2.15 The flue system may now be connected to the stove, ensure

that all joints are sealed with a suitable fire resistant sealant.

It is also recommended that a physical retention method be

used at the flue spigot joint, self-tapping screws being

favoured.

2.16 Connect a suitable pressure gauge to the test point located

on the inlet fitting, and turn the gas supply on. Light the

stove and check all gas joints for gas soundness. Turn the

stove to maximum and check that the supply pressure is as

stated on the data badge. Turn the gas off and replace the

test point screw, turn the gas on and check the test point for

gas soundness.

3.1 Place the flame baffle onto the burner and push against the

rear tray lip. See diagram 11.

3.2 Locate the rear panel against the spacer brackets and slide

down so that it locates on the ledge of the flame baffle. See

diagram 12.

3.3 Locate the front coal between the heat shield and the flame

baffle so its ends sit flat on the burner skin. See diagram 13.

3.4 Place five of the loose round coals on the front coal so they

lean against the flame baffle, in between the fingers. Place

the two rectangular coals against the reflector panels, one

either side, behind the front row of loose coals. See

diagram 14.

3.5 Place four of the loose round coals behind the first row so

that they sit on the fingers, the two outer ones should touch

the rectangular coals. See diagram 15.

3.6 Place the three remaining coals behind the centre row so

that they touch the back panel. See diagram 16.

4.1

After laying out the coals, replace the glass panel. Tighten

the six pozidrive screws, working from the top down. Do

not over tighten. Lower the front door on by holding at 90

degrees to the appliance and lowering down on to the two

hinge pins. See diagram 17.

3. FUEL BED ARRANGEMENT

13

INSTALLATION INSTRUCTIONS

INSTALLATION

12

13

14

15

16

AR0361

AR0362

11

AR0363

AR0364

AR0360

AR0359

4. DOOR REPLACEMENT

17

AR1363