background image

7

PRODUCT DESIGN

TRIP POINT

COIL COVER

PRESSURE

SWITCH

COIL COVER

PRESSURE

SWITCH

PART #

TRIP POINT
ID BLOWER

PRESSURE

SWITCH

ID BLOWER

PRESSURE

SWITCH

PART #

TRIP POINT

COIL COVER

PRESSURE

SWITCH

TRIP POINT
ID BLOWER

PRESSURE

SWITCH

HIGH

ALTITUDE KIT

GMH950453BXA*

-1.30

-1.10

-0.52

-0.37

-0.37

20197312

-1.10

0130F00000P

TBD

TBD

TBD

GMH950703BXA*

-1.10

-0.95

-0.52

-0.37

-0.37

20197312

-0.95

0130F00002P

TBD

TBD

TBD

GMH950704CXA*

-1.30

-1.10

-0.52

-0.37

-0.37

20197312

-1.10

0130F00000P

TBD

TBD

TBD

GMH950904CXA*

-1.40

-1.20

-0.75

-0.60

-0.60

20197310

-1.20

0130F00001P

TBD

TBD

TBD

GMH950905DXA*

-1.30

-1.10

-0.52

-0.37

-0.37

20197312

-1.10

0130F00000P

TBD

TBD

TBD

GMH951155DXA*

-1.30

-1.10

-0.75

-0.60

-0.60

20197310

-1.10

0130F00000P

TBD

TBD

TBD

NEGATIVE

PRESSURE

ID BLOWER

WITH FLUE

FIRING

TYPICAL

SEA

LEVE

DATA

(2)

NEGATIVE

PRESSURE

COIL COVER

WITH FLUE

FIRING

TYPICAL

SEA

LEVE

DATA

(2)

NEGATIVE

PRESSURE

COIL COVER

WITH FLUE

NOT FIRING

TYPICAL

SEA

LEVEL

DATA

(1)

(2) Data given is the least negative pressure required for pressure switch to remain closed.

PRESSURE SWITCH TRIP POINTS AND USAGE CHART

(1) Data given is least negative pressure required for pressure switch to close.

MODEL

0 to 7,000 ft.

PRESSURE SWITCH TRIP POINTS AND USAGE

7,001 to 11,000 ft.

NEGATIVE

PRESSURE

ID BLOWER

WITH FLUE

NOT FIRING

TYPICAL

SEA

LEVEL

DATA

(1)

Part Number

20162903

20162904

Open Setting (°F)

160

150

GMH950453BXA*

1

GMH950703BXA*

1

GMH950704CXA*

1

GMH950904CXA*

1

GMH950905DXA*

1

GMH951155DXA*

1

T.O.D. PRIMARY LIMIT