8 8.8.2 description of diagnostic tests – Furuno CSH-5L/CSH-8L User Manual
Page 78
8. MAINTENANCE, TROUBLESHOOTING
8-8
8.8.2
Description of diagnostic tests
Single test, Conti(nuous) test
The single and conti(nuous) tests check the ROMs and RAMs for proper
operation, one time or continuous, respectively. After the test is completed, the
results are indicated as OK (normal operation) or NG (malfunction), to the right
of the device checked. For the single test, normal operation is restored after
completion of the test. When the [MENU] key is pressed in the continuous test,
the equipment goes into start up condition.
CONTI TEST
MAIN-0 1050729-XX.XX F FF
ROM
= OK
RAM
= OK
VRAM
= OK
EEPROM (P.W) = OK
TRX
1050
***
-XX.XX
1050
###
-XX.XX
FF FF
ROM
= OK
RAM
= OK
DROM = OK
KEY-0
1050730-XX.XX F
ROM
= OK
RAM
= OK
XX.XX: Program Version No.
*** : 742 (CSH-5L 55 kHz, 68 kHz)
735 (CSH-8L 85 kHz)
736 (CSH-8L 107 kHz)
### : 733 (CSH-5L 55 kHz)
734 (CSH-5L 68 kHz9
735 (CSH-8L 85 kHz)
736 (CSH-8L 107 kHz)
F : DIP SW setting
Control unit’s program
version no. and results
of ROM and RAM tests.
0 = Version No. of Board
Transceiver unit’s program
version no. (CSH-5L only)
and results of ROM, RAM
and DROM* tests.
Processor unit’s program version no.
and results of ROM, RAM, VRAM
and EEPROM tests.
0 = Version No. of Board
PRESS [MENU] KEY TO EXIT
* = Continuous test
only
Continuous test (example: CSH-5L, 55 kHz transducer)