beautypg.com

Burner and nozzle specifications – Hotpoint GE750DX User Manual

Page 5

background image

GB

5

Burner and nozzle specifications

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal

power

kW

(p.c.s.*

Thermal

power

kW

(p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Thermal

power

kW

(p.c.s.*)

Nozzle

1/100

Flow*

l/h

Ridot.

Nomin.

(mm)

(mm)

***

**

Nomin.

(mm)

Reduced Fast (RR)

100

0,70

2,60

41

80

189

186

2,60

110 (Y)

248

Semi Fast (S)

75

0,40

1,65

30

64

120

118

1,65

96

157

Auxiliary (A)

55

0,40

1,00

30

50

73

71

1,00

79

95

Double flame (DCDR internal)

30

0,30

0,90

27

44

65

64

0,90

74

86

Double flame

(DCDR internal)

130

1,50

4,60

27

44

327

321

5,00

74

476

(DCDR external
2 nozzle)

55

70 x 2

119 x 2

Supply
Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

*

At 15°C and 1013 mbar - dry gas

**

Propane

P.C.S. = 50.37 MJ/Kg

***

Butane

P.C.S. = 49.47 MJ/Kg

Natural

P.C.S. = 37.78 MJ/m

3

RR

S

S

A

DCDR

GE750D