BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
C. LOCATION AND CLEARANCES
1. APPLIANCE LOCATIONS AND SPACE
REQUIREMENTS
Figure 1 illustrates a variety of ways the appliance may
be located in a room. The Builder's Choice Series may
be installed directly on the floor or on a hearth. These
appliances are certified for installation in a bedroom,
bed/sitting room or in mobile homes in the U.S. and
Canada.
2. CLEARANCES
a. For the appliance:
Top of standoffs
0
Floor
0
Back of appliance
1/2
Sides
1/2
Front Face to Ceiling
30
b. Minimum Venting Clearances (see Figure 2).
1) Horizontal runs off of the back of the
appliance to the wall shield:
0 above the top of the appliance standoffs
1 sides and bottom of the vent
2) Horizontal runs inside a wall (heat shields
must be installed)
3 air space on top of the vent
1 from sides and bottom of vent
3) Vertical runs
1 air space around the vent
Figure 1 - Appliance Locations
Note:
Dimensions represent minimum space required
for a centered corner installation. Actual requirements
will vary with individual construction.
Figure 2 - Rear Vented Appliances Venting Clearances
WARNING!
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Dimensions