beautypg.com

Operation, Warning – Homelite HP275 User Manual

Page 7

background image

7

099238

6. Close propane supply valve.

3. Open propane supply valve on propane tank(s) slowly.

Note:

If not opened

slowly, excess-flow check valve on propane tank will stop gas flow. If this
happens, close propane supply valve and open again slowly.

4. Push in and hold automatic control valve button (see Figure 4).
5. Push piezo ignitor button (see Figure 4). You may need to push the piezo

ignitor button 3-8 times until the pilot lights.

Note:

Hose may be filled with

air. If so, keep automatic control valve button pressed and wait 20 seconds
before pressing ignitor button again. When pilot lights, keep automatic control
valve button pushed in. Release button after 30 seconds.

Figure 4 - Main Burner Valve Handle, Automatic Control Valve Button, and

Piezo Ignitor Button Locations

LP-PFA/OV 006

Gas Controls-TrashCan

Piezo Ignitor
Button

Main Burner
Valve Handle

Continued

5. Check all connections for leaks. Apply mixture of liquid soap and water to gas

joints. Bubbles forming show a leak that must be corrected.

OPERATION

To Start Heater

1. Follow all installation, ventilation, and safety information.
2. Locate heater on stable and level surface. Make sure strong drafts do not blow

on heater.

Automatic
Control Valve
Button

!

WARNING

Never use an open flame to check for a leak. Apply a mixture
of liquid soap and water to all joints. Bubbles forming show a
leak that must be corrected. Correct all leaks at once.

!

WARNING

Fully close main burner valve before lighting pilot. If not,
severe burns can occur. Do this by turning valve handle
towards the OFF position until it stops.

!

WARNING

Review and understand the warnings in the Safety Informa-
tion Section. They are needed to safely operate this heater.
Follow all local codes when using this heater.