3-1.

Front Panel Controls

1

Optional Voltage/Wire Speed
Meter

2

Optional Voltage/Wire Speed
Switch

Use to choose volts or wire feed
speed display.

3

Optional Remote Voltage
Control

Use to set welding power source
voltage at the wire feeder. Numbers
are for reference only.

4

Wire Speed Control

5

Jog/Purge Switch

Use Jog position to momentarily
feed welding wire at speed set on
Wire Speed control without ener-
gizing welding circuit or shielding
gas valve.

Use Purge position to momentarily
energize gas valve to purge air from
gun or adjust gas regulator.

6

Trigger Hold Switch

Push up to weld without holding gun
trigger throughout the weld cycle.

To start weld cycle, press and re-
lease gun trigger within three se-
conds after an arc has been struck.
To end weld, press and release gun
trigger.

Power switch is on rear panel (see
Section 2-5)

192 503-C

2

3

4

5

1

6