beautypg.com

Hotpoint GE75DX User Manual

Page 4

background image

GB

4

4. Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used.

Sticker are available from any of our Service Centres.

• Adjusting the burners’ primary air :
Does not require adjusting.

• Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw,

which is positioned in or next to the tap pin, until the

flame is small but steady.

3. Having adjusted the flame to the required low setting,

while the burner is alight, quickly change the position of

the knob from minimum to maximum and vice versa

several times, checking that the flame does not go out.

4. Some appliances have a safety device (thermocouple)

fitted. If the device fails to work when the burners are

set to the low flame setting, increase this low flame

setting using the adjusting screw.

5. Once the adjustment has been made, replace the seals

on the by-passes using sealing wax or a similar

substance.

DATA PLATE

Electrical

connections

See data plate

This appliance conforms to the

following European Economic

Community directives:

-73/23/EEC dated 19/02/73 (Low

Voltage) and subsequent

amendments

- 89/336/EEC dated 03/05/89

(Electromagnetic Compatibility)

and subsequent amendments

- 93/68/EEC dated 22/07/93 and

subsequent amendments.

- 90/336/EEC dated 29/06/90

(Gas) and subsequent

amendments.

- 2002/96/EC

If the appliance is connected to liquid gas, the regulation

screw must be fastened as tightly as possible.
Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used.

Stickers are available from any of our Service Centres.
Should the gas pressure used be different (or vary

slightly) from the recommended pressure, a suitable

pressure regulator must be fitted to the inlet pipe (in order

to comply with current national regulations).

This manual is related to the following products: