beautypg.com

Installation instructions, Operation instructions – haier S125ENF User Manual

Page 10

background image

8

Installation instructions

·

Operation instructions

y Connection method of water supply pipeline in the houses where a solar water heat

coexists with another type of water heater

y Operation methods:

1. Before using hot water, valves K1, K2 and K3 must be in closed state;

2. To fill water, open valve K1. When water flows out from the overflow pipe, it indicates the water tank is full.

At this time, close valve K1.

3. To use hot water, open valve K2. Hot water will come out from the shower nozzle. If it is too hot, open valve

K3 to adjust the water temperature.

4. Close valves K2 and K3 after use.

To the tank of the solar water heater

Another type of

water heater

When a solar water heat coexists
with another type of water heater,
check valves must be installed on
both cold and hot water pipes to
avoid damage caused by reverse
water flow from tank of another
heater, which has higher pressure,
to that of the solar heater.

Tap water

Solar water heater

Vent

Overflow

Water inlet and outlet

Tap water

Check

valve

This manual is related to the following products: