beautypg.com

Qualified service personnel only – Hafler TRANSANA TRM10S User Manual

Page 28

background image

– 19 –

!

Qualified Service Personnel Only

Power On/Off Circuit
The power on/off circuit is designed to turn the amplifier on slowly and
off quickly. When AC power is initially applied to the subwoofer, AC
signals on the secondary of the power transformer are negatively
rectified through CR2 and CR7 into peak holding capacitor C31, and
divided by R19 and R20. When the resulting DC voltage at pin 2 of
U15A is lower than the reference voltage of -1.4 at pin 3, the output of
U15 goes high, allowing the soft start circuitry to slowly turn on the
amplifier. When AC power is removed from the subwoofer, pin 2 very
quickly goes toward 0V and flips U15A low to -15V, immediately
turning the amplifier off before the power supplies collapse.

Signal Sensing Turn-On Circuit
The amplifier will not turn on until an input signal is detected. The
first stage of the detection circuit amplifies the WOOFER signal by
40dB - to insure that even the smallest input signal is detected - and
high pass filters it to eliminate DC offset errors. This amplified signal
is negatively rectified by CR9 and held by C85. When the voltage at
pin 6 of U16B goes lower than the -0.15V reference at pin 5, the
output goes high, allowing the soft start circuitry to turn the amplifier
on. After signal is removed, the 470-second time constant of C85 and
R145 will discharge slowly towards 0V until it is higher than -0.15V,
causing U16B to go low to -15V, turning the amplifier off.

Thermal Protection
The thermal protection turns off the amplifier when the heatsink
reaches an excessively high temperature. This condition is detected by
the NTC (Negative Temperature Coefficient) thermistor TS2. At higher
temperatures, TS2 has a lower resistance - causing a higher voltage at
pin 6 of U15B. When this voltage exceeds the reference voltage at pin
5, the output of U15B goes low to -15V and turns the amplifier off.

POWER ON / OFF

REFERENCE

CR15

R18

COMPARATOR

U15A

ON / OFF

CR5

AC POWER

RECTIFIER

CR2,CR7
R12, C31
R19, R20

SIGNAL AMPLIFIER

U16A

R57, R75

C28, C84

SIGNAL

RECTIFIER

AND HOLD

CR9, R145

C85

REFERENCE

R103, R84

COMP

U16B

ON / OFF

CR3

SIGNAL SENSING TURN-ON

THERMAL PROTECTION

TEMP

TS2, R147

COMPARATOR

U15B

R22, R23

ON / OFF

CR6

This manual is related to the following products: