Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05

19

1. "STOP!" Read the safety information on previous

page.

2. Open the control access cover (logs #3 and 4 in

CFL models) or (logs #4 and 5 in ST-CFL
model), refer to your Log Placement Instructions.

3. Turn the valve control knob to the "OFF"

position. To do this, you must turn the knob
clockwise

to the "Pilot" position, and

then press in and continue turning
clockwise

to the "OFF" position.

GAS CONTROL VALVE

NOTE: Knob cannot be turned from "PILOT" to

"OFF" unless knob is pushed in slightly. Do not
force.

4. WAIT FIVE (5) MINUTES TO CLEAR OUT

ANY GAS. Then smell for gas, including near
the floor. If you then smell gas, STOP! Follow
"B" in the safety information previous page. If
you don't smell gas, go to the next step.

5. The pilot should not require accessing for

lighting purposes. The pilot is located at the
end of the burner.

THERMOPILE

PILOT BURNER

6. To put the control in the "Pilot" position, turn the

control knob counter-clockwise

to the

"Pilot" position.

7. To light the pilot depress the control knob and then

depress the red piezo button until it makes a
clicking sound. It may be necessary to repeat this
step. If the pilot does not light after 10 seconds, go
back to step 3. The control knob should be held
down for a MINUTE after pilot ignition.

• If the control knob does not pop out when

released, STOP-shut off the gas supply to
the fireplace control valve, and IMMEDI-
ATELY
call your service technician or gas
supplier.

• If the pilot will not stay lit after two tries, turn

the control knob to the "OFF" position and
call your service technician or gas supplier.

8. After the pilot has been lit, the burner can be turned

on by turning the knob counter-clockwise

to the "ON" position. Flip the ON/OFF

switch to the "ON" position. (This is located to the
right on the burner leg and behind the control
access cover.)

9. Close control access cover.

1. Turn ON/OFF switch to "OFF".

2. Open the control access cover.

3. Turn the valve control knob clockwise

to the "Pilot" position, then depress knob and
continue turning to "OFF" position.

4. Close control access cover.

TO TURN OFF GAS APPLIANCE

LIGHTING INSTRUCTIONS

LIGHTING INSTRUCTIONS