beautypg.com

How to use the chest pulse sensor – Healthrider HRTL16900 User Manual

Page 6

background image

6

HOW TO PUT ON THE CHEST PULSE SENSOR

The chest pulse sensor consists of two components:
the chest strap and the sensor unit (see the drawing
below). Insert the tab on one end of the chest strap into
one end of the sensor unit, as shown in the inset draw-
ing. Press the end of the sensor unit under the buckle
on the chest strap. The tab should be flush with the
front of the sensor unit.

Next, wrap the
chest pulse sen-
sor around your
chest and attach
the other end of
the chest strap to
the sensor unit.
Adjust the length
of the chest strap,
if necessary. The
chest pulse sen-
sor should be under your clothing, tight against your
skin, and as high under the pectoral muscles or
breasts as is comfortable. Make sure that the logo on
the sensor unit is facing forward and is right-side-up.

Pull the sensor unit away from your body a few inches
and locate the two electrode areas on the inner side.
The electrode areas are the areas covered by shallow
ridges. Using saline solution such as saliva or contact
lens solution, wet both electrode areas. Return the
sensor unit to a position against your chest.

CHEST PULSE SENSOR CARE AND MAINTENANCE

• Thoroughly dry the chest pulse sensor after each

use. The chest pulse sensor is activated when the
electrode areas are wetted and the heart rate
monitor is put on; the chest pulse sensor shuts off
when it is removed and the electrode areas are
dried. If the chest pulse sensor is not dried after

each use, it may remain activated longer than nec-
essary, draining the battery prematurely.

• Store the chest pulse sensor in a warm, dry place.

Do not store the chest pulse sensor in a plastic bag
or other container that may trap moisture.

• Do not expose the chest pulse sensor to direct

sunlight for extended periods of time; do not expose
it to temperatures above 122° Fahrenheit (50°
Celsius) or below 14° Fahrenheit (-10° Celsius).

• Do not excessively bend or stretch the sensor unit

when using or storing the chest pulse sensor.

• Clean the sensor unit using a damp cloth—never

use alcohol, abrasives, or chemicals. The chest
strap may be hand washed and air dried.

CHEST PULSE SENSOR TROUBLE-SHOOTING

The instructions on the following pages explain
how the chest pulse sensor is used with the con-
sole. If the chest pulse sensor does not function
properly, try the steps below.

• Make sure that the chest pulse sensor is under your

clothing, tight against your skin, and as high under
the pectoral muscles or breasts as is comfortable.
The logo on the sensor unit must be facing forward
and be right-side-up. Note: If the chest pulse sensor
does not function when positioned as described, try
moving it slightly lower or higher on your chest.

• Use saline solution such as saliva or contact lens

solution to wet the two electrode areas on the
sensor unit. If heart rate readings do not appear until
you begin perspiring, re-wet the electrode areas.

• As you walk or run on the treadmill, position your-

self near the center of the walking belt.

For the

console to display heart rate readings, the user
must be within arm’s length of the console.

• The chest pulse sensor is designed to work with

people who have normal heart rhythms. Heart rate
reading problems may be caused by medical
conditions such as premature ventricular contrac-
tions (pvcs), tachycardia bursts, and arrhythmia.

• The operation of the chest pulse sensor can be

affected by magnetic interference caused by high
power lines or other sources. If it is suspected that
this is a problem, try relocating the treadmill.

• The CR2032 battery may need to be replaced (see

page 27).

HOW TO USE THE CHEST PULSE SENSOR

Chest Strap

Tabs

Sensor Unit

Tab

Sensor

Unit

Buckle