Summary of connections, Trigger data dip switch settings, Ntsc output configuration (dip switch 1 – 3) – Honeywell Optiflex User Manual
Page 19: Ntsc guard tour mode – camera dwell time, Ntsc guard tour mode – camera selection

6-1
S E C T I O N 6
Summary of Connections
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
optiflex-SOC-V3
DIP
SWITCH
23
4
5
6
1
ON
78
COMPOSITE
VIDEO
OUT
10 baseT
ETHERNET
CAMERA INPUTS
(DETAIL C)
N.C.
-GND
TRIGGER 5
TRIGGER 6
TRIGGER 4
TRIGGER 8
GND
TRIGGER 7
TRIGGER 2
TRIGGER 3
TRIGGER 1
ECP GRN
ECP YEL
+12V
DETAIL C
DETAIL A
DETAIL B
PRESS
AND HOLD BOTH
(10 SECONDS)
UNIT RESET
DETAIL A
DETAIL B
1
2
3
4
5
6
Trigger Data
DIP Switch Settings
NTSC Output Configuration (DIP Switch 1 – 3)
Dip Switch
Cam-1
View
Cam-2
View
Cam-3
View
Cam-4
View
Cam-5
View
Cam-6
View
Guard
Tour
Reserved
1
OFF ON OFF ON OFF ON ON OFF
2 OFF
OFF
ON
ON
OFF
OFF
ON ON
3
OFF OFF OFF OFF ON ON ON
ON
NTSC Guard Tour Mode – Camera Dwell Time
Dip Switch
2 sec
4 sec
8 sec
16 sec
4 OFF ON OFF ON
5 OFF
OFF
ON
ON
Function Voltage
Trigger
(+12VDC)
Camera 1
1
Camera 2
2
Camera 3
3
Camera 4
4
Camera 5
5
Camera 6
6
NTSC Advance
7
All Cameras
8
NTSC Guard Tour Mode – Camera Selection
Dip Switch
Use All Six Cameras for
Guard Tour
Use the First Four
Cameras for Guard Tour
6 OFF
ON