Caution, Electrical information, Warning – Hearth and Home Technologies Dakota 42-B User Manual
Page 14

14
Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev J 11/08
Battery polarity must be correct or module damage will
occur.
CAUTION
A. Intellifi re Ignition System Wiring
• This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
• This appliance is supplied with a battery pack which is
located in the ON/OFF switch terminal box. A wiring
diagram is shown in Figure 7.1.
• The battery pack requires two D cell batteries (not
included). See Section 12.B. for battery replacement.
7
7
Electrical Information
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
CAUTION
Shock Risk
• Replace damaged wire with type 105° C
rated wire.
• Wire must have high temperature
insulation.
WARNING
IGNITION MODULE
3 VAC
GRN
ORG
INTERMITTENT
PILOT
IGNITOR
IGNITION
MODULE
(3V)
ON/OFF
WALL
SWITCH
LOW VOLTAGE
BATTERY
PACK
FLAME SPARKER/
SENSOR
SEE NOTE 1
ORG
WHT
PIGGYBACK
ON/OFF SWITCH
BRN
BRN
VALVE
VALVE
GROUND TO
FIREPLACE
CHASSIS
I
S
BLACK
RED
BATTERY
PACK
Figure 7.1 Intellefi re Pilot Ignition (IPI) Wiring Diagram