Troubles treatment

Phenomenon

No water supply

The temperature
isn't high enough

Possible reason

The tank is empty

The pipeline or the connection
is impeded

The evacuated tubes have
damaged

The water supply is paused or low

water pressure

The pipeline or the connection is

Damaged

Valve for water supply is unstuck

or already damaged

The evacuated tube can't work
effectively for there are hindrance

in front of it

Treatment

Supply water according to the

manual

Maintain the pipeline or clean
the connection

Replacing the tubes

Waiting for the supplying again

Maintain the pipeline and
the connection

Screw down the valve or
replacing it

Change the location or move

the hindranc

Using Instruction

11

The controller
can't reach the
programmed
level or there is
no water

Too much ash on the tube

Tidy the tube

Packing list

Main parts

Quantity

Storage
tank

box

Storage tank

Manual

Frame box

Tank
bracket
box

Left support

bracket

Right

support

bracket

Evacuated tubes

Controller box

1

1

1

1

1

1

1

1

1

1

2

25

1

1

2

30