Specifications, H200l features and benefits – Hellenbrand H-200L Series User Manual
Page 2
![background image](/manuals/97240/2/background.png)
DEALER NAME:
Hellenbrand, Inc.
404 Moravian Valley Rd
Waunakee, WI 53597
www.hellenbrand.com
73-047L
1/08-LBRY
Web Brochure Only
HELLENBRAND WARRANTY
Go to www.hellenbrand.com for full details.
FLOW
PEAK FLOW BACK BRINE TANK
1
DEMAND
CAPACITY
RATE
RATE
WASH
MINERAL
TANK
SALT
MODEL
MINERAL
LOW SALT
MED. SALT
HIGH SALT
@
@
RATE
TANK
SIZE
STORAGE
NAME
CU. FT.
GRAINS/LBS. GRAINS/LBS.
GRAINS/LBS.
15 PSI
25 PSI
GPM
(INCHES)
(INCHES) (POUNDS)
H200L-60
2
38,000/12
56,000/20
64,000/30
34
44
4.2
1354
18x40
330
H200L-90
3
57,000/18
84,000/30
96,000/45
34
44
4.2
1465
18x40
300
H200L-120
4
76,000/24
112,000/40
128,000/60
41
53
5.3
1665
24x41
640
H200L-150
5
95,000/30
140,000/50
160,000/75
46
59
7.5
1865
24x50
750
H200L-150-21
5
95,000/30
140,000/50
160,000/75
54
68
9.0
2162
24x50
750
H200L-180
6
114,000/36
168,000/60
192,000/90
44
56
7.5
1865
24x50
750
H200L-180-21
6
114,000/36
168,000/60
192,000/90
53
67
9.0
2162
24x50
750
H200L-210
7
133,000/42
196,000/70
224,000/105
51
66
9.0
2162
24x50
710
H200L-240
8
152,000/48
224,000/80
256,000/120
58
74
12.0
2472
24x50
680
H200L-270
9
171,000/54
252,000/90
288,000/135
55
72
12.0
2472
30x50
1110
H200L-300
10
190,000/60
280,000/100
320,000/150
54
70
12.0
2472
30x50
1110
Specifications
H200L Features and Benefits
• 2.0" Inlet & Outlet provides higher service flows with
less pressure drop
• 1.5" Distributor Pilot
• 12-Volt Operation
• Electronic Meter Demand with Calendar Day Override
• Scrolling User Screen shows capacity remaining, time
of day and flow rate
• 12-Volt Relay Driver allows dry contact signal
• Service Interval Screen reminds you to call for
preventative maintenance service
• Differential Pressure Switch Capability
• Fully Programmable Cycle Position and Times
• Nine Cycle Control
• Soft Water Brine Tank Re-Fill
• Multiple Backwash and Rinse Capabilities
• Quiet Operation
• Variable Reserve automatically adjusts to changing
water usage patterns.
• Several programming options including: variable re-
serve, fixed reserve, calendar day override, delayed or
immediate regeneration.
• Diagnostics
–Days since last regeneration
–Gallons since last regeneration
–Gallon reserve capacity last 7 days
–63 Days history of daily totals usage
–Maximum flow rate for the last seven days
–Total number of regenerations
–Total days in service
–Total gallons processed
• Permanent memory backup of all programming
• 10 Year Battery Life - 2-1/2 years Time of Day Backup
• Uses less than $2 of electricity per year
System Designs Options
Single
Twin Parallel
Twin Alternating
Meter Accuracy
Model: H200L
Flow Ranges 1.5-75 GPM
Accuracy: ±5%
1
Suggested brine tank size with grid plate option.
H200L Standard Valve/Tank Thread Connection