Technical data, Installation, Unpacking – Husqvarna BREEZE QC 720 User Manual
Page 7: Position, Electrical connection

35
Technical data
Model
QC 520
QC 620
QC 720
Airflow
Max.
320 m ³/h x) 180 m ³/h 320 m ³/h x) 180 m ³/h 320 m ³/h x) 180 m ³/h
Min.
160 m ³/h
160 m ³/h
160 m ³/h
Size
Height
45 mm
45 mm
45 mm
Width
498 mm
598 mm
698 mm
Depth
445 mm
445 mm
445 mm
Light
Max 11 W PL
Max 11 W PL
Max 11 W PL
Grease filter
1 pc.
1 pc.
1 pc.
Voltage
230 V
230 V
230 V
Total power
111 W
111 W
111 W
x) Valid when the cooker hood is fitted with carbon filter.
Fig. 5
Installation
Fig. 4
Unpacking
Check that the cooker hood is not damaged.
Transportation damages should immediately be
reported to the transport company. Damages, faults
and eventually missing parts should immediately be
reported to the retailer. Dispose carefully of the
packaging material so that it is out of the way of small
children. Remove the transport supports (C-Fig. 9).
Position
The cooker hood should be mounted freely hanging on
the wall. The cooker hood must be at least 40 cm
above electric burners or electric range (Fig. 5). The
cooker hood is not approved for mounting above gas
burners or gas range.
498 / 598
/ 698
465
45
Min
40
cm
Electrical connection
The electric outlet should be placed above the cooker
hood or inside a wall cupboard. The hood has a power
cord and moulded plug with earth connection for a
wall outlet of 230V.