beautypg.com

Hoshizaki KMS-1400MLH User Manual

Page 38

background image

38

Problem

Possible Cause

Remedy

[4] Water continues to

be supplied in freeze
cycle (outside of
refill).

a) Fill or Harvest Water

Valve

1. Diaphragm does not

close.

1. Check for water leaks with

icemaker off.

b) Control Board

1. Defective.

1. See "II.C.4. Control Board

Check Procedure".

[5] No water comes from

spray tubes. Water
pump will not start, or
freeze cycle time is
too short.

a) Water Supply Line

1. Water pressure too

low and water level in
water tank too low.

1. Check and get

recommended pressure.

b) Fill or Harvest Water

Valve

1. Dirty mesh filter or

orifice and water level
in water tank too low.

1. Clean.

c) Water System

1. Water leaks.

1. Check connections for

water leaks, and replace.

. Clogged.

. Clean.

3. Drain valve leaking by. 3. Check assembly and

clean.

d) Pump Motor

1. Motor winding

opened.

1. Replace.

. Bearing worn out.

. Replace.

3. Wiring to pump motor. 3. Check for loose

connection or open, and
replace.

4. Defective capacitor.

4. Replace.

5. Defective or bound

impeller.

5. Replace or clean.

6. Mechanical seal worn

out.

6. Check and replace.

e) Control Board

1. Defective.

1. See "II.C.4. Control Board

Check Procedure".

[6] Fan motor will

not start, or is not
operating.

a) Fan Motor

1. Motor winding

opened.

1. Replace.

. Bearing worn out.

. Replace.

3. Wiring to fan motor.

3. Check for loose

connection or open, and
replace.

4. Defective capacitor.

4. Replace.

5. Fan blade bound.

5. Check and replace.

b) Magnetic Contactor

1. Bad contacts.

1. Check for continuity and

replace.

[7] All components

run, but no ice is
produced.

a) Refrigerant

1. Undercharged.

1. Check for leaks and

recharge.

. Air or moisture

trapped.

. Replace drier and

recharge.

b) Compressor

1. Defective valve.

1. Replace.

c) Hot Gas Valve

1. Continues to open in

freeze cycle.

1. Check and replace.

d) Liquid Line Valve

1. Continues to close in

freeze cycle.

1. Check and replace.

e) Fill or Harvest Water

Valve

1. Water valve is wide

open during freeze
(outside of refill).

1. Check for water leaks.