beautypg.com

2. reset button and low battery indicator, 3. lens delay control, Section 3-2 – Hobart Welding Products HOOD XVX User Manual

Page 6: See section 3-2), See section 3-3)

background image

OM-240 362 Page 4

3-2. Reset Button And Low Battery Indicator

.

The auto-darkening lens turns on
(darkens) automatically when

welding begins and turns off 15 −

20 minutes after welding stops.

1

Reset Button

Press Reset button to check if the lens

is working properly.

When the Reset button is pressed, the

lens should darken twice and return to

the clear state. Do not use the helmet

if the lens does not function as de-

scribed. (See Section 9, Trouble-

shooting.)
2

Low Battery Indicator

The low battery indicator lights when

2−3 days of battery life remain.

If battery power is low, replace with

CR2450 lithium batteries (2 required)

(Hobart Part No. 770 284) (see Sec-

tion 6).

1

2

3-3. Lens Delay Control

1

Lens Delay Control

The lens delay control is used to ad-

just the time for the lens to switch to

the clear state after welding.

The delay is particularly useful in

eliminating bright after-rays present

in higher amperage applications

where the molten puddle remains

bright momentarily after welding.

Lens delay adjusts from min (0.10

second) to max (1.0 second.).

1