beautypg.com

5. installing work clamp, 6. setting gun polarity for wire type – Hobart Welding Products BETA-MIG 2250 User Manual

Page 15

background image

OM-192 440 Page 11

2-5.

Installing Work Clamp

1

Work Cable

Route cable out front panel opening
from inside.

2

Negative (–/Black) Output
Terminal

Connect cable to terminal.

3

Hardware

4

Work Clamp

Route cable through clamp handle
and secure as shown.

Close door.

Ref. ST-802 285 / Ref. ST-801 566

Tools Needed:

1/2, 3/4 in

2

1

3

4

2-6.

Setting Gun Polarity For Wire Type

Tools Needed:

3/4 in

1

1

Polarity Changeover Label

2

Positive (+/Red) Output
Terminal

3

Negative (–/Black) Output
Terminal

Always read and follow wire
manufacturer’s recommended
polarity.

Close door.

3

2

Ref. ST-801 875

Ref. ST-192 432