A. Wiring Requirements

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

• This appliance comes standard with a 120 VAC cord

assembly which has a female plug in to accommodate
all control options and accessories. See Figure 10.1.
This is required for proper operation of the appliance
(IntelliFire Ignition). An outlet box may be installed in a
bottom back corner of the existing solid fuel masonry or
factory built fi replace to plug in the cord assembly, or the
supplied power cord may be routed out onto the hearth
to a nearby outlet.

• A 120 VAC circuit for this product must be protected with

ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.

• Low voltage and 120 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire
120V to the valve or to the appliance wall switch. Incor-
rect wiring will damage controls.

• An IntelliFire Plus™ ignition system is standard with this

appliance.

10

10

Electrical Information

B. IntelliFire Plus™ Ignition System Wiring

• Wire an outlet box (120VAC) in the bottom back corner of

the existing solid fuel masonry or factory built fi replace to
plug in the cord assembly. The supplied cord assembly
may also be routed out onto the hearth to a nearby outlet.

WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.

• Refer to Figure 10.1, IPI Wiring Diagram.

• This appliance is equipped with an IntelliFire Plus™

control valve which operates on a 6 volt/1.5 AMP
system.

• Plug the 6 volt transformer plug into the cord assembly to

supply power to the insert OR install 4 AA cell batteries
(not included) into the battery pack before use.

ON/OFF Switch

• An ON/OFF switch is included with the appliance

surround and should be attached to surround/facing.
(See Installation instructions for remote control/fronts).

• If desired an additional wall switch or thermostat may

be added to system as shown in Figure 10.1.

Figure 10.1 IPI Wiring Diagram

BLK

RED

BATTERY PACK

6V DC

GROUND

BROWN

GREEN

(MAIN)

ROCKER

SWITCH

ORANGE

(PILOT)

WALL SWITCH

OR REMOTE

INSTALL

TO CORD ASSEMBLY

120VAC

INTERMITTENT
PILOT IGNITOR

RC100 RC200 RC300

(OPTIONAL WALL CONTROLS)

TO CORD

ASSEMBLY

(110V)

WHT

ORG

MODULE

FLAME

MODULATION

AUX1 AUX2

AUX300 MODULE

FAN

BLK

RED

AUX2 NOT USED FOR INSERT MODELS.