Section 5 − installation, 1. installing welding generator – Hobart Welding Products CHAMPION 10 User Manual
Page 20

OM-945 Page 16
SECTION 5 − INSTALLATION
!
Do not move or operate unit
where it could tip.
!
Do not lift unit from end.
!
Do not weld on base. Welding
on base can cause fuel tank fire
or explosion. Bolt unit down
using holes provided in base.
!
Always securely fasten weld-
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.
Do not install unit where air flow is re-
stricted or engine may overheat.
.
See Section 4-2 for lifting eye rat-
ing.
Mounting:
!
Do not mount unit by support-
ing the base only at the four
mounting holes. Do not use
flexible mounts. Use cross-
supports to adequately sup-
port unit and prevent damage
to base.
6
Cross-Supports
Mount unit on flat surface or use
cross-supports to support base.
install2 2008-01 − Ref. 800 652 / Ref. 800 477-A / 803 274-A / 804 712
OR
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Location / Airflow Clearance
5-1. Installing Welding Generator
Mounting
OR
1