Safety precautions – haier AD142ALEAA User Manual

Page 6

background image

5

2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent

or a similar qualified person.

3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.

4. The wiring method should be in line with the local wiring standard.

1. Applicable ambient temperature range:

The machine is adaptive in following situation

5. The power cable and connecting cable are self-provided.

For series 142, 182 the power cable should be H05RN-F 3G 2.5mm

2

.

For series 242 the power cable should be H05RN-F 3G 4.0mm

2

.

The connecting cable should be H05RN-F 4G 0.75mm

2

.

All the cables shall have got the European authentication certificate. During installation,

when the connecting cables break off, it must be assured that the grouding wire is the last

one to be broken off.

6. The breaker of the air conditioner should be all-pole switch; and the distance between its

two contacts should not be no less than 3mm. Such means for disconnection must be

incorporation in the fixed wiring.

7. The indoor unit installation height is at least 2.5m.

8. The distance between its two terminal blocks of indoor unit and outdoor unit should not

be over 5m. If exceeded, the diameter of the wire should be enlarged according to the local

wiring standard.

9. The waste battery shall be disposed properly.

Safety Precautions

Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 6
20 27 15
14.5 -- --
7 24 -7
6 18 --

Cooling

Heating

Indoor

outdoor

DB C
WB C
DB C
WB C

Indoor

outdoor DB C

WB C

DB C
WB C

Cooling

Heating

Indoor

outdoor

Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --

DB C
WB C
DB C
WB C

Indoor

outdoor DB C

WB C

DB C
WB C

For *.EAA :

For *.ERA :